CMSV6Help Center
/
839 DOCS · 211 VIDEOS中文

Acquire real-time alarm of equipment

Author 刘勇Updated 2026-05-09 10:29:19Doc ID 1427628 words · 3 min readView original ↗

Interface description

Acquire real- time alarm of equipment

Request parameters

https://v7.cmsv8.com/StandardApiAction_vehicleAlarm.action?jsession=66d754dd7f41473dbd2&DevIDNO=013300000001&toMap=0

Request parameters

Parameter name Parameter type Must Example Parameter meaning
jsession string Yes 66d754dd7f41473dbd2 Session number
devIdno string No 013300000001 Equipment number, if the equipment number is blank, query all equipment of the account
toMap number No 0 Map coordinate conversion: 0 means WGS84 coordinate (default);1 means Google coordinates (gj02);2 means Baidu coordinates (bd09)

Return parameters

Parameter Name parameter Type meaning of parameters
result number interface status code, 0 is normal, and other information is abnormal. For more information, see [Error Code Description](/helpCenter/doc/index.html?isStudy=1&pageType=3&docId=1321&type=1&lang=en "Error Code Description").
alarms array alarm data
info number alarm information
desc string alarm Description
atp number for details about the alarm type, see [Alarm Type Description](/helpCenter/doc/index.html?isStudy=1&pageType=3&docId=1324&type=1&lang=en "Alarm Type Description").
did string equipment No.
vid string if the license plate number is queried by equipment number, it is empty.
cid number company ID (Company)
etm number alarm End Time (UTC) Seconds
stm number alarm Start Time (UTC) Seconds
guid string alarm Unique Number
p1 number for details about alarm parameter 1, see [Alarm Type Description](/helpCenter/doc/index.html?isStudy=1&pageType=3&docId=1324&type=1&lang=en "Alarm Type Description").
p2 number for details about alarm parameter 2, see [Alarm Type Description](/helpCenter/doc/index.html?isStudy=1&pageType=3&docId=1324&type=1&lang=en "Alarm Type Description").
p3 number for details about alarm parameter 3, see [Alarm Type Description](/helpCenter/doc/index.html?isStudy=1&pageType=3&docId=1324&type=1&lang=en "Alarm Type Description").
p4 number for more information about alarm parameters, see [Alarm Type Description](/helpCenter/doc/index.html?isStudy=1&pageType=3&docId=1324&type=1&lang=en "Alarm Type Description").
img string for picture information; separated, it is an http address path, which can be multiple picture information.
hd number processing status 1 means processed, 0 means unprocessed
hdu string processing user id
hdc string processing content
hdt string processing time
ss1 number for details about the alarm start status 1, see [Alarm Status Description](/helpCenter/doc/index.html?isStudy=1&pageType=3&docId=1326&type=1&lang=en "Alarm Type Description").
ss2 number for details about the alarm start status 2, see [Alarm Status Description](/helpCenter/doc/index.html?isStudy=1&pageType=3&docId=1326&type=1&lang=en "Alarm Type Description").
ES1 number for details about the alarm end status 1, see [Alarm Status Description](/helpCenter/doc/index.html?isStudy=1&pageType=3&docId=1326&type=1&lang=en "Alarm Type Description").
ES2 number for details about the alarm end status 2, see [Alarm Status Description](/helpCenter/doc/index.html?isStudy=1&pageType=3&docId=1326&type=1&lang=en "Alarm Type Description").
slng number alarm start longitude
slat number alarm start latitude
elng number alarm end longitude
elat number alarm End Latitude
ssp number alarm start speed unit: km/h, divided by 10 during use
esp number alarm end speed unit: km/h, divided by 10 during use
slc number alarm start mileage Unit: m
elc number mileage at the end of alarm Unit: m
smlng string the converted longitude of the alarm start map longitude
smlat string the converted latitude of the alarm start map latitude
emlng string the converted longitude of the map after the alarm ends
emlat string the converted latitude of the map after the alarm ends
sps string the geographical location of the alarm start geographical location or (the longitude of the alarm start map, the latitude of the alarm start map)
eps string the geographical location after the end start geographical location resolution or (longitude of the alarm end map, latitude of the alarm end map)
createtime string update time
pagination object paging information
totalPages number total number of pages of query data
currentPage number current Query Page Number
pageRecords number number of entries per page
totalRecords number total number of query data

Return Example

{
  "alarmlist": [
    {
      "DevIDNO": "013300000001",
      "Gps": {
        "dct": 0,
        "gd": 37,
        "gt": "2024-12-07 15:19:57",
        "hx": 40,
        "lat": 22515410,
        "lc": 0,
        "lid": 2991,
        "lng": 113916914,
        "mlat": "22.518160",
        "mlng": "113.928299",
        "net": 0,
        "pk": 256,
        "s1": 1,
        "s2": 0,
        "s3": 0,
        "s4": 0,
        "sfg": 0,
        "snm": 0,
        "sp": 0,
        "sst": 0,
        "t1": 0,
        "t2": 0,
        "t3": 0,
        "t4": 1172,
        "tsp": 0,
        "yl": 0
      },
      "desc": "SBAC=48423131313134241207151957000600",
      "guid": "00013300000001241207151957000600",
      "hd": 0,
      "img": "6",
      "info": 0,
      "p1": 1,
      "p2": 0,
      "p3": 0,
      "p4": 0,
      "rve": 0,
      "srcAt": 0,
      "srcTm": "2024-12-07 15:19:57",
      "stType": 613,
      "time": "2024-12-07 15:19:57",
      "type": 613
    }
Source help.cmsv7.com