1、 function description
Only the data before 10 minutes can be queried during the historical playback query. Customers are not satisfied with this, so we can adjust it slightly. Configuring it for 1 minute will cause the gps table of mysql data to be very large and may have problems.
2、 operating instructions
Add the following parameters to CMSServerV6\bin\libgpsstore_808.ini and save:
[CONFIG]
; Less than or equal to 100 online equipment, storage interval, default 5 minutes 180000 milliseconds = 3 minutes
100_DeviceGpsUpdateInterval = 180000
1000_DeviceGpsUpdateInterval = 180000
2000_DeviceGpsUpdateInterval = 180000
Over2000_DeviceGpsUpdateInterval = 180000
Note: If there is no libgpsstore_808.ini file in the CMSServerV6\bin directory, you need to create it manually.